Building better technology
for the civil engineering industry

Building better technology
for the civil engineering industry

Tel: +44 (0)118 945 3737

Tel: +44 (0)118 945 3737

VJTech Limited Mobile Logo

signin Login register Register Tel: +44 (0)118 945 3737

Back

Unsaturated Triaxial Testing (Double Wall Cell) System


Pro Unsaturated Triaxial Testing (Double Wall Cell) System

For prices: call +44 (0)118 945 3737 or Email us
The VJ Tech Unsaturated Triaxial Testing (Double Wall Cell) System enables variable suctions to be applied whilst providing accurate measurement of soil volume change. The double wall cell allows the inner and outer cell pressures to be kept at the same value by the Cell Pressure Controller thus eliminating the volume change due to cell expansion.
The Pore Water Pressure controller provides an accurate measurement of water entering or leaving the sample whilst the Automatic Volume Change device (which is connected to the inner cell pressure line) provides the total volume changes of the specimen.
The new Double Wall Cell design separates the Inner Cell completely from the Outer Cell. It has 6 valves for air/water flow (inner cell pressure, outer cell pressure, 2 base water pressure & 2 top cap water/air pressure) and is designed with specially coated material to minimise corrosion.
The Cell base has 7 exit ports, allowing On-Sample Transducers, 2 Bender Elements or a Mid-Pore Pressure Transducer to be fitted, with data logging captured by the additional Input sockets on the TriSCAN Pro Advanced and the Pro Dual APC.

Unsaturated Triaxial Testing (Double Wall Cell) System

Available Configuration Possibilities:

 

Note: This table summarises ALL available options - obviously some combinations are incompatible. The User can select the most suitable configuration for the testing requirements and contact VJ Tech for additional advice on the optimum System setup.

TriSCAN Pro Load Frame Capacity      
50 or 100 kN (11240 or 22480 psi)
Double Wall Triaxial Cell Size   
100 mm (4 inch)
Sample Sizes  38, 50, 70, or u to 101 mm (1.5, 2, 2.75 or 4 inch)
Load Cells 2, 3, 5, 10 or 20 kN (450, 675, 1124, 2248 or 4496 lbf)
Water Distribution Panel 4-way, 6-way or 8-way 

Product Documentation

Pro Automatic Unsaturated Triaxial Testing datasheet
Download

Accessorize your purchase with these related items

Clisp Studio Unsaturated Software Module
Clisp Studio Unsaturated Software Module
TriSCAN Pro 50 kN (11240 lbf) Advanced Load Frame
TriSCAN Pro 50 kN (11240 lbf) Advanced Load Frame
Pro Dual Automatic Pressure Controller 3500 kPa (508 psi)
Pro Dual Automatic Pressure Controller 3500 kPa (508 psi)
Pro Pneumatic APC (Single Channel) 1 MPa
Pro Pneumatic APC (Single Channel) 1 MPa
Automatic Volume Change Device with Displacement Transducer
Automatic Volume Change Device with Displacement Transducer
Double Wall Triaxial Cell for Unsaturated Testing
Double Wall Triaxial Cell for Unsaturated Testing
Internal Submersible Load Cells
Internal Submersible Load Cells
25mm LSCT Displacement Transducer
25mm LSCT Displacement Transducer
Pressure Transducer (10 bar)
Pressure Transducer (10 bar)

No Videos currently available for this product