Clisp Studio Rowe Software Module


Part Number : VJT-csROWE
For prices: call +44 (0)118 945 3737 or Email us
The VJ Tech Clisp Studio Rowe Software module enables the User to perform a Rowe Cell consolidation test to determine the magnitude and rate of consolidation of a sample using hydraulic vertical load.

The software conforms to BS1377-6.

Clisp Studio Rowe Software Module

csROWE Features:

  • Optional Swelling Stage
  • User defined Saturation cycles (ramp and check)
  • User defined Consolidation cycles (Loading, Holding and Unloading phases)
  • Customisable System Units
  • Easy instrument and equipment setup and calibration
  • Tests can be set up and run on an individual client, job, borehole and sample basis
  • Easy test setup using wizard style Assistant
  • Automated Test Control 
  • User configurable data logging
  • On screen calculation of t50 and t90 values
  • E-mail test status
  • Live view of sensor readings and status
  • Live Data Views
    • Swelling Data View (Measured Input Data, Initial Displacement, Specimen Stress, Swelling Pressure)
    • Saturation Raw Data View (Measured Input Data, Calculated B-Value)
    • Consolidation Live Data (Measured Input Data, Initial Vertical Stress, Initial PWP, Initial Settlement, Time)
    • Consolidation Results Data (Target Stress, Initial Temperature, Final Temperature, t50, t90, Secondary Compression, Voids Ratio, Compressibility, Consolidation, Cumulative Change in Height)
  • Live graphical display of logged and calculated data
    • Swelling Data Graph (Time vs Specimen Stress)
    • Saturation Raw Data Graph (Time vs Pore Water Input)
    • Saturation Results Graph (Vertical Stress Input vs B-Value)
    • Consolidation Graphs
      • Undrained Loading (Time vs Pore Water Input)
      • PWP Consolidation (Time vs PWP Dissipation)
      • Settlement Consolidation (Time vs Cumulative Change in Height)
      • Volume Change Consolidation (Time vs Cumulative Change in Volume)
      • Specimen Stress Graphs (Effective Specimen Stress vs Voids Ratio/Settlement/Consolidation/Compressibility)
  • Live tabular display of logged and calculated data
    • Swelling Data Table (Time, Vertical Stress Input, Strain Input, Swelling Pressure, Pore Water Input)
    • Saturation Data Table (Time, Pore Water Input, Vertical Stress Input, Volume Input)
    • Saturation Results Table (Vertical Stress Input, Back Pressure Input, Pore Water Input, B-value)
    • Consolidation Tables
      • Undrained Loading (PWP) Table (Time, Pore Water Input, Vertical Stress Input, Strain Input, Specimen Stress, Volume Input)
      • Drained Consolidation Table (Time, Pore Water Input, Vertical Stress Input, Strain Input, Back Pressure Input, Volume Input, Effective Specimen Stress, PWP Dissipation, Cumulative Change in Height & Cumulative Change in Volume)
  • User configurable views, graphs and tables (customisable from Input, Measured and Result data)
  • Customised presentation reports on request

Detailed product specifications

Requires Windows operating System Windows 7 Pro or later

Switchable between multiple languages

Data stored in MS SQL database

Data export in industry standard formats

 