Building better technology
for the civil engineering industry

Building better technology
for the civil engineering industry

Search

Tel: +44 (0)118 945 3737

Tel: +44 (0)118 945 3737

VJTech Limited Mobile Logo Search

 Login  Register Tel: +44 (0)118 945 3737

 
     

CLISP Studio Release 2.10.1.0

Dec 16 2020



1.1 - Introduction

Clisp Studio version 2.10.1.0 is the final revision released to the public in 2020. This update to Clisp Studio includes the introduction of new testing standards, bug fixes and some feature upgrades.

 

 

1.2 - New Standards

Clisp Studio following on from the recent introduction of new BS EN standards in the UK for soil testing now includes support for BS EN 17892-10 for Direct Shear tests.

 

 

1.2.1 – Standards Supported in CS Shear

The CS shear module now includes support for the following test standards:

BS1377 – 7 (1995) – Determination of Shear Strength by Direct Shear

BS EN 17892 – 10 (2018) – Direct Shear Test

ASTM D3080-04 – Direct Shear Test of Soils under Consolidated Drained Conditions

ASTM D3080-D3080M-11 – Direct Shear Test of Soils under Consolidated Drained Conditions

AS 1289.6.2.2 : 1998 – Determination of the shear strength of soil – Direct Shear Test using a Shearbox

Q181C – Effective Angle of Internal Friction at Constant Volume Conditions for Granular Materials

 

 

1.3 - New Features

A number of new features have been introduced into Clisp Studio relating to calibration of transducers using Pro series instruments. A new excel export feature has also been introduced.

 

 

1.3.1 – Ghost Channels

Clisp now supports the option to store multiple calibrations on a single channel. This allows multiple transducers to be stored on one channel so that the most appropriate transducer can be selected for the test without the need to recalibrate it.

 

 


1.3.2 – Soft Tare Function

A soft tare function has been introduced for channels calibrated in load on Pro Series instruments. This allows the user to zero a load cell (to remove drift) without effecting the calibration of the load cell.

 

 

 

1.3.3 – All Input Values Excel Export

From the main export menu a new option is available that allows a test to be exported to excel so that all transducer inputs values from a test will be displayed on a single excel spreadsheet. This allows a user to see the entire history of a test easily, without needing to move to differing tabs or files.

 

 


1.4 – New Instruments

Support for new automatic pressure controllers has also now been included. The new models are VJT2266-P7 (100 bar pressure controller), VJT2266A-P14 (140 Bar Pressure Controller) and VJT2266A-PHS (high speed pressure controller).

 

 


1.5 – Other News

This version of Clisp Studio also includes the following:

 

·         Support for the New Ringshear Pro

·         A number of bug fixes and improvements across the new BS EN triaxial standard tests

·         CS Marshall now includes a user defined setup allowing nonstandard tests to be performed.

 

 

1.6 - Fixed Cases

 

Case

Title

Status

6296

CS Ringshear - Manually stopping a schedule with wait after stop and then starting another schedule causes clisp to hang

Resolved (Fixed)

6295

csTriax - BS En ISO 17892 CU&CD tests (csEffectiveTriax) - Cell and Back pressures at shear stage

Closed (Fixed)

6294

csTriax - BS EN ISO 17892-9 standard (CU - csEffectiveTriax) - After stop control for the load frame

Closed (Fixed)

6291

k0 csTriaxialADV = fix for height

Closed (Fixed)

6290

CS dyan - importing script the test data isn't displayed in clisp

Closed (Fixed)

5288

csSimpleShear - ASTM D6528-17 - Shear stage doesn't trigger

Closed (Fixed)

5287

csShear - Q181C - Shear summary graph doesn't include the peak shear stress

Closed (Fixed)

5286

Soil Steel Interface ringshear test plan - Error message when adding additional fast shear stages

Closed (Fixed)

5285

csShear - ASTM D3080-11 - Shear report needs to include the vertical stress

Closed (Fixed)

5284

Shearscan Pro - Engage button on horizontal axis in Clisp studio

Closed (Fixed)

5282

csShear - BS 1377-7 - Residual shear - Reverse speed bounches back to the default

Closed (Fixed)

5280

Clisp studio - Ghost channels - FSD and Divisions at Full Scale are not copied

Closed (Fixed)

5277

soil steel interface ringshear - vertical displacement transducer reading is wrong

Closed (Fixed)

5276

csBender - List of changes needed

Closed (Fixed)

5274

Clisp Studio - exporting calibrations that have ghost channels

Closed (Fixed)

5273

Clisp Studio - Ghost channel issue with units

Closed (Fixed)

5272

cs oedo - Mv is using wrong unit

Closed (Fixed)

5271

soil steel ringshear test plan - reverse stage doesn't use the speed entered in setup

Closed (Fixed)

5268

cs ringshear - shear stage setup, UI formatting covering some of the setup

Closed (Fixed)

5267

cs ringshear - old ASTM and BS standard - Preshear not traveling in right direction

Closed (Fixed)

5266

ghost calibration channel issue - working range cannot be set independently

Closed (Fixed)

5265

Issue with Ghost channel calibration

Closed (Fixed)

5264

cs ringshear feature request - add additional graph to shear stage of BS EN standard test

Closed (Implemented)

5263

Soil Steel Interface Ringshear test plan - issues with stopping a Pro series ringshear

Closed (Fixed)

5262

creating a test issue - can't access standards drop down

Closed (Fixed)

5260

End Of Primary Consolidation (csOedo)

Resolved (Implemented)

5259

shearscan pro firmware 1.65 issues

Closed (Fixed)

5258

csTriax (csTotalTriax) - BS EN ISO 17892-8 standard - Shear setup window gets corrupted

Closed (Fixed)

5254

csShear - Calculation of the target load in consolidation should take into account the platen correction

Closed (Fixed)

5253

Shear modules - Platen correction applied to the Normal Stress

Closed (Fixed)

5252

custom images in reports

Resolved (Fixed)

5251

Cs simple shear and Cs Dynadss report issues

Closed (Fixed)

5249

CS res - remove membrane correction from Q137

Closed (Fixed)

5248

csDYNA - Cosmatics issue in Ko consolidation Initial Data window

Closed (Fixed)

5247

New Instrument Variants DSC3003M / MM

Closed (Implemented)

5246

Clisp studio - AGS export function

Closed (Fixed)

5245

(Untitled)

Closed (Fixed)

5244

csTriax - BS EN ISO 17892-9 CU CD tests - Cosmetics issue in consolidation initial data screen

Closed (Fixed)

5243

Q137 - First Run of newly created test

Closed (Fixed)

5242

csRes AG Standard Engage Schedule

Closed (Fixed)

5241

cs triax - Total stress New AS standard - Error message when trying to run shear schedule

Closed (Fixed)

5239

CS dynadss - Absolute waveforms (load control) are not starting from 0 load

Closed (Fixed)

5238

exception message in cs dyna

Closed (Fixed)

5234

cs res -  q137 standard - deviator stress calculation change

Closed (Fixed)

5233

csTriax - ASTM UU tests - Membrane correction

Closed (Fixed)

5232

RingShear pro Vertical Load

Closed (Approved)

5231

csTriax - UU tests using a Triscan pro - Shear rate improvement

Closed (Fixed)

5230

CS triax - be en cu triaxial - DSC3000 unloads after the aniotropic schedule goes into a maintained state

Closed (Fixed)

5229

CS triax - BE EN Standard - Open and close back pressure valve message not working

Closed (Fixed)

5228

csTriax - UU (total stress) Temperature Controlled tests (all standards) - Triggering conditions

Closed (Fixed)

5226

csTriax - Temperature controlled tests - ASTM CU&CD tests - Hardware setup cannot be applied

Closed (Fixed)

5225

csShear - Residual direct shear. (new BS ENISO standard)

Closed (Fixed)

5224

cs res - q137 standard - stopping condition variable (IsCycleCountReady) needs cycle active added to definition

Closed (Fixed)

5223

csRingshear - ASTM D6467-13 - Preshear schedule automation

Closed (Fixed)

5222

DSC3000 - restarting automatically after restart shouldn't do this

Closed (Fixed)

5221

cs dyandss - shear schedules have the same trigger condition shown twice

Closed (Fixed)

5220

cs dynadss - exception message

Closed (Fixed)

5219

csTriax - BS1377-8 standard (effective stress) - t100 label is showing t50

Closed (Fixed)

5217

csMarshall - New Test Variant

Closed (Implemented)

4214

Analogue Channels - Soft Tare

Closed (Implemented)

4212

Analogue Channel Calibration Sets

Closed (Implemented)

4206

csDYNA - Axial strain calculation in the Stress Path stage

Closed (Fixed)

4183

CS host - adding second stage causes time to break

Closed (Fixed)

2648

csDYNA, csDYNADSS, csDYNADSS-C - Replace "Miantain current position" with "Maintain current level"

Closed (Fixed)

 


Latest Posts

Introduction to Direct Simple Shear (DSS) Testing
1/26/2021 9:45 AM | adrian@vjtech.co.uk
CLISP Studio Release 2.10.1.0
12/16/2020 9:52 AM | adrian@vjtech.co.uk
Clisp Studio 2.9.0.0 Release
10/8/2020 1:54 PM | vasileios@vjtech.co.uk
Introduction to Permeability Testing
9/11/2020 10:23 AM | Irina@vjtech.co.uk
Introduction to unsaturated triaxial testing
7/3/2020 2:27 PM | vasileios@vjtech.co.uk

Categories


Archives

2021 Jan 48 1
2020 Dec 11 1
2020 Oct 72 1
2020 Sep 1192 1
2020 Jul 929 2
2020 Apr 94 1
2020 Feb 59 1
2019 Nov 2019 1
2019 Oct 42 1
2019 Jul 80 1
2019 Jun 148 3
2019 May 4355 1
2018 Mar 17770 1
2017 Oct 49668 1
2017 Aug 464 1
2016 Sep 68 1
2016 Aug 96 1
2016 Jul 7 1
2016 May 29 1
2016 Apr 67 1
2016 Mar 34 1
2016 Feb 156 3
2016 Jan 120 1
2015 Dec 34 1
2015 Nov 137 1
2015 May 283 1
2015 Mar 931 4
2015 Feb 760 1
2014 Nov 2467 8
2014 May 508 6
2014 Apr 497 7
2014 Mar 1375 12
2013 Dec 82 1

Tags