Building better technology
for the civil engineering industry

Building better technology
for the civil engineering industry

Tel: +44 (0)118 945 3737

Tel: +44 (0)118 945 3737

VJTech Limited Mobile Logo

 Login  Register Tel: +44 (0)118 945 3737

 
     
Clisp Studio 2.9.0.0 Release

Clisp Studio 2.9.0.0 Release

Oct 08 2020

New Clisp Studio Release

  1. Introduction

Clisp Studio version 2.9.0.0 is the second major revision released to the public in 2020. This significant update to Clisp Studio includes the introduction of new testing standards across many modules, addition of new instruments and many feature upgrades.

  1. Newly implemented Standards in Clisp Studio

Following recent revisions introduced by ASTM and BSI a number of new standards are now supported within Clisp Studio complementing the existing supported standards. The following standards have been introduced:

    1. BS EN ISO 17892, Part 10 (2018) - Direct Shear Tests – New standard

 

    1. BS EN ISO 17892, Part 10 (2018) - Ring Shear tests – New standard

 

    1. ASTM D3080/D3080M – 11 – Direct  Shear Tests of Soils Under Consolidated Drained Conditions - Revised standard

 

    1. ASTM D4767-11 (Reapproved 2020) – Consolidated Undrained Triaxial Compression Tests for Cohesive Soils - Revised standard

 

    1. AS1289.6.4.2 - 2016 – Consolidated Undrained triaxial tests - Revised standard

 

    1. ASTM D6927- 15 – Marshall Stability and Flow of Asphalt Mixtures - Revised standard

 

    1. ASTM D7181-20 – Consolidated Drained Triaxial Compression Test for Soils – Revised standard

 

    1. ASTM D4186 – 12 – One-Dimensional Consolidation Properties of Saturated Cohesive Soils Using Controlled-Strain Loading (CRS tests) - Revised standard

 

    1. ASTM D6528-17 – Consolidated Undrained Direct Simple Shear Testing of Fine Grain Soils – Revised standard

 

  1. New Features

    1. Expansions of the types of triaxial test methods that can be used on a Temperature – Controlled Triaxial system

 

    1. Marshall tests (BS EN 12697-34: 2012) – More options are added to tailor the tests based on individual requirements

 

    1. Test reports have been added for the permeability tests (all standards)

 

    1. Test reports have been added to the CRS tests

 

    1. Photos of the soil specimens (before and after testing) can be added into the triaxial testing reports

4. New Instruments

New instrument User Interfaces have been added to Clisp Studio to be used by the software in soil testing.

 

         i. Dual axis DSC-1000MM Pro Series instrument is now available in Clisp studio and can be used to run static/cyclic simple shear tests and direct shear   tests (hardware is required)

        ii. Standard and Advanced types of Shear Test Pro series instruments are now available in Clisp studio and can be used to run direct shear tests (hardware is required)

       iii. Advanced Ring Shear Pro Series instrument is now available in Clisp studio and can be used in Ring Shear tests (hardware is required)

Fixes (Cases)

5249 CS res - remove membrane correction from Q137 - checked in Clisp version 2.9.0.4085 Closed (Fixed)

5246 Clisp studio - AGS export function - checked in Clisp version 2.9.0.4082 Closed (Fixed)

5245 (Untitled) - checked in Clisp version 2.9.0.4082 Closed (Fixed)

5244 csTriax - BS EN ISO 17892-9 CU CD tests - Cosmetics issue in consolidation initial data screen - checked in Clisp version 2.9.0.4085. Closed (Fixed)

5243 Q137 - First Run of newly created test - fixed Closed (Fixed)

5242 csRes AG Standard Engage Schedule - checked in Clisp version 2.9.0.4085 Closed (Fixed)

5241 cs triax - Total stress New AS standard - Error message when trying to run shear schedule - checked in Clisp version 2.9.0.4082 and is fixed Closed (Fixed)

5239 CS dynadss - Absolute waveforms (load control) are not starting from 0 load - non issue, working correctly as discussed, Closed (Fixed)

5238 exception message in cs dyna - cant replicate, will close and re-open if required Closed (Fixed)

5234 cs res - q137 standard - deviator stress calculation change - checked in Clisp version 2.9.0.4085 Closed (Fixed)

5233 csTriax - ASTM UU tests - Membrane correction - checked in Clisp version 2.9.0.4085 Closed (Fixed)

5232 RingShear pro Vertical Load - ok, default text changed as indicated. Closed (Approved)

5231 csTriax - UU tests using a Triscan pro - Shear rate improvement - No further action. Closed (Fixed)

5230 CS triax - be en cu triaxial - DSC3000 unloads after the anisotropic schedule goes into a maintained state - checked in Clisp version 2.8.0.4075 Closed (Fixed)

5229 CS triax - BE EN Standard - Open and close back pressure valve message not working - checked in Clisp version 2.9.0.4082 Closed (Fixed)

5228 csTriax - UU (total stress) Temperature Controlled tests (all standards) - Triggering conditions - Checked in v2.8.0.4059. Case is closing Closed (Fixed)

5226 csTriax - Temperature controlled tests - ASTM CU&CD tests - Hardware setup cannot be applied - Checked in v2.8.0.4059 Case is closing Closed (Fixed)

5225 csShear - Residual direct shear. (new BS ENISO standard) - Changed. New Test Plan V2.09 Closed (Fixed)

5224 cs res - q137 standard - stopping condition variable (IsCycleCountReady) needs cycle active added to definition - fixed Clisp version 2.9.0.4082 Closed (Fixed)

5223 csRingshear - ASTM D6467-13 - Preshear schedule automation - Checked in v2.8.0.4059. Case is closing. Closed (Fixed)

5222 DSC3000 - restarting automatically after restart shouldn't do this - checked in Clisp version 2.9.0.4082 Closed (Fixed)

5221 cs dyandss - shear schedules have the same trigger condition shown twice - checked in Clisp version 2.8.0.4059 Closed (Fixed)

5220 cs dynadss - exception message - checked in Clisp version 2.8.0.4059 Closed (Fixed)

5219 csTriax - BS1377-8 standard (effective stress) - t100 label is showing t50 - Checked in v2.8.0.4059 Case is closing Closed (Fixed)

5217 csMarshall - New Test Variant - all looks good in Clisp version 2.8.0.4075 Closed (Implemented)

4216 CS Shear - BS EN test method - unticking residual test option can delete test data - checked in Clisp version 2.8.0.4047 Closed (Fixed)

4215 CS Shear - BS EN standard - Update to Shear stage setup UI. Closed (Implemented)

4211 DSC3000 - Allow Zero time in User waveforms Closed (Fixed) 4210 csOdo-astm- cv parameter - checked in Clisp version 2.9.0.4085 Closed (Fixed)

4209 csSD-SWCC - Volume change and Vertical settlement reset when starting Adsorption stage - Checked in v2.8.0.4059. Case is closing Closed (Fixed)

4208 csDYNA - The Pore Pressure Change variable is not plotted correctly on the Cyclic Time Related Curves graph - Fixed. The PP was not logged! The fix requires new test Plan V1.64 Closed (Fixed)

4207 csDYNA - Displacement target at cyclic schedules resets when Ramp&Maintain control is used - Cannot reproduce Resolved (Fixed)

4206 csDYNA - Axial strain calculation in the Stress Path stage - Case is closing without any further action. Closed (Fixed)

4202 csDYNA - Improving the calculation of corrected height in isotropic consolidation schedule - Done. No changes to the plan needed, but the option is cleared and hidden when using suction caps. Closed (Implemented)

4200 csDYNA - Limit the test time value - No action. Closed (Fixed)

4199 Clisp testing of DSC-1000M - Firmware version 1.62 is under testing Resolved (Fixed)

4198 Shear modules - Calculation of platen weight correction - Changes checked in v2.8.0.4036 Change has been implemented in all the before mentioned standards. Case is closing. Closed (Fixed)

4196 CS Dynadss - the logging interval of cyclic schedule changes whilst schedule is running if test assistant is opened - not seen for a long time, closing case Closed (Fixed)

4195 cs dynadss - hardware not being set from hardware assistant - checked in Clisp version 2.9.0.8042 Closed (Fixed)

4193 cs res - cycle count still corrupts during cyclic schedule - not seen for a long time, closing case Closed (Fixed)

4192 CS Marshall - feature request - add elapsed time stopping condition to test assistant - checked in Clisp version 2.9.0. Closed (Implemented)

4191 cs dyna - Hardware assigning issue - not seen for a long time Closed (Fixed)

4190 cs triax - ASTM CU/CD effective stress - trigger issue during BP step/ramp. - checked in Clisp version 2.9.0.4082 Closed (Fixed)

4189 cs dynadss-c - multiple of graphs can be opened at the same time - leave it as is. Closed (Fixed)

4188 CS triax advanced - Ramp schedule needs take final reading checked - checked in Clisp version 2.8.0.4000 Closed (Implemented)

4187 VJT2760A Shear test - Fixed - this model was missing from the list Clisp maintains. Closed (Fixed)

4186 Dynamic Tests - Cycle Count Reached Stopping Conditions - it’s not the count Closed (Won't Fix)

4185 csConstantShear -Static Push-Pull tests - Missing variable from live view - Checked in v2.8.0.3992. Case is closing. Closed (Fixed)

4184 csSimpleShear - Pre-release check - Changes done in Test Plan version V1.17 Closed (Fixed)

4183 CS host - adding second stage causes time to break - checked in Clisp version 2.9.0.4082 Closed (Fixed)

4182 csRingShear - BS EN ISO 17892-10 standard - Shear stage procedure needs to be updated - Fixed. The automata has been updated. Closed (Fixed)

4181 csShear - ASTM D6528-12 standard should be removed from the module - checked in v2.8.0.3992 Case is closing Closed (Fixed)

4180 csShear - all standards - Take Initial Value at the first Shear schedule - Case is closing Closed (Fixed)

4179 csShear - BS En ISO 17892-10 - VLoad is not applied correctly in the shear stage - Checked in v2.8.0.3992 Case is closing Closed (Fixed)

4178 csShear - BS EN ISO 17892-10 standard at Shearscan 2 instrument - Case is closing, Shearscan 2 should run the firmware version 3.43 in order to apply correctly the vertical load in multiple consolidation schedules (like in the new BS EN ISO 17892-10 standard). Case is closing Closed (Fixed)

4177 cs host error message when removing channels - checked in Clisp version 2.8.0.3992 Closed (Fixed)

4176 csRingshear - ASTM D6467-13 standard - Pre-release check - Checked in v2.8.0.3992 Case is closing Closed (Fixed)

4175 cs perm - Perm schedules automation not working - checked in Clisp version 2.8.0.3992 Closed (Fixed)

4174 csRingshear - BS EN ISO 17892-10 standard - Pre-release check - Checked in v2.8.0.3992. Case is closing Closed (Fixed)

4173 csRingShear BS1377 standard - Exception thrown when the consolidation data table is open - checked in v2.8.0.3986 Case is closing Closed (Fixed)

4172 csTriaxADV - Valve message - Matteo Closed (Fixed)

4171 cs perm - add warning message in test creating for new standards - checked in Clisp version 2.8.0.3984 Closed (Implemented)

4170 cs perm - add addition info to ASTM test method description - checked in Clisp version 2.8.0.3984 Closed (Fixed)

4169 cs perm - Rowe test method shows two standards not supported - checked in Clisp version 2.8.0.3984 Closed (Fixed)

4168 cs perm error messages - checked in Clisp version 2.8.0.3992 Closed (Fixed)

4167 DSC1000M - Initial Development. Closed (Fixed)

4166 csShear - AS1289 standard - pre-Release check - Checked in v2.8.0.3992 Case is closing Closed (Approved)

4165 cs perm - Rowe cell - report summary seems to have formatting issue. - checked in Clisp version 2.8.0.3983 Closed (Fixed)

4164 csShear - ASTM D6528-17 standard - Pre-release check - Checked in v2.8.0.3992. Case is closing Closed (Fixed)

4163 csTriax- ASTMD 4767-11 (2020) - Solenoid issue during engage.  Closed (Fixed)

4162 cs res - The permanent deformation schedule seems to be missing a stop condition - checked in Clisp version 2.8.0.4054 Closed (Responded)

4161 cs dynadss - cyclic schedule using user defined waveform goes straight to maintain state when started - checked in Clisp version 2.8.0.4059 and is no longer seen Closed (Fixed)

4160 cs dynadss - using encoder as feedback for horizontal displacement cause the shear stage to go the wrong direction - checked in Clisp version 2.8.0.4059 Closed (Fixed)

4159 cs dynadss - Running a shear schedule with displacement transducer feedback the H servo won't move - checked in Clisp version 2.8.0.4003 Closed (Fixed)

4158 CS resilient - control stop put the schedule into a maintained state. Closed (Fixed)

4157 cs dyna - user defined waveform with DSC3000 allow zero time to be entered - fixed, allowed and can be imported with a waveform as well. Closed (Fixed)

4156 cs dyna - user defined waveform not working when using relative position - Checked in Clisp version 2.8.0.4000 Closed (Fixed)

4154 cs dyna - cyclic schedule using saw tooth the cycle count isn't updating. - have completed a significant amount of tests and haven't seen any issues so closing the case Closed (Fixed)

4153 cs dynadss-c - liquefaction schedule - unexpected movement in H servo at the start of schedule - checked in Clisp version 2.8.0.4059 Closed (Fixed)

4152 cs dynadss-c - cyclic stage starts but there is no movement from the servo's - not seen for a long time. closing case Closed (Fixed)

4151 csShear - BS En ISO standards - Pre-Release checks - Checked with Clisp v2.8.0.3982 Case is closing Closed (Fixed)

4150 csShear - BS1377 - Pre-release check - Fix checked in v2.8.0.3982 Case is closing Closed (Fixed)

4149 csTriax - Expansion of temperature controlled tests in UU total stress tests - Checked in v2.8.0.3992 Case is closing Closed (Implemented)

3146 Shearscan pro - Firmware 1.60 - Connection problems - checked in Clisp version 2.9.0.4085 Closed (Fixed)

3140 cs dyna - when a schedule is started after cell pressure is dropped to 0kPa - closing as the issue seems to be from the APC. The APC had lost its DAC linearisation. Once restored the issue in this case disappears. Closed (Fixed)

3111 CS Dyna - Cyclic schedule doesn't stop when using user defined wave forms - checked in Clisp version 2.8.0.4028 Closed (Fixed)

3101 Cs Res - second PD schedule isn't auto stopping and then duplicates data set once manually stopped - issues not seen for a while. Clisp version 2.9.0.4085 most recently tested without showing issues Closed (Fixed)

2989 cs res - cycle count jumping around from actual value Closed (Fixed)

2984 CD Dyna - ramp schedule (displacement control) initially moves in the wrong direction Closed (Fixed)

2968 DYNADSS DSC3000MM - cyclic schedule not logging data - haven't seen for a log time, closing case Closed (Fixed)

2938 cs dyandss - typo on initial data window for cyclic logging - checked and seen in Clisp version 2.8.0.4059 Closed (Fixed)

2893 CS Dyna - exporting table causes time to lose milliseconds - issue no longer seen Closed (By Design)

2885 csDYNA - Minor and cosmetic issues - checked in Clisp version 2.8.0.4047 Closed (Fixed)

2861 DSC-3000 - Last cycle is not consistent, the last rough is not going to the target Closed (Not Reproducible)

2725 csDynaDSS-C - Log all channels when using DSC3000 - this was done some time ago. Closed (Implemented)

2633 csDyna - Cyclic Schedules - Copy the last schedule not the first - check in Clisp version 2.8.0.4047 Closed (Implemented)

2204 DSC3000M - writing calibration from Clisp to instrument causes the channel to be corrupted - not seen the issue for a while, so closing case Closed (Fixed)

2117 csDYNA - Manual intervention request unchecks when consolidation initial data opens – fixed Closed (Fixed)

Total: 0 Comment(s)

Latest Posts

Clisp Studio 2.9.0.0 Release
10/8/2020 1:54 PM | Vasileios
Introduction to Permeability Testing
9/11/2020 10:23 AM | Irina
Introduction to unsaturated triaxial testing
7/3/2020 2:27 PM | Vasileios
Introduction to Bender Element testing
7/3/2020 2:04 PM | Vasileios
CLISP Studio Release 2.7.0.0
4/23/2020 3:09 PM | Adrian Rose

Categories


Archives

2020 Oct 61 1
2020 Sep 189 1
2020 Jul 446 2
2020 Apr 87 1
2020 Feb 54 1
2019 Nov 1575 1
2019 Oct 38 1
2019 Jul 76 1
2019 Jun 144 3
2019 May 3510 1
2018 Mar 14783 1
2017 Oct 43269 1
2017 Aug 428 1
2016 Sep 65 1
2016 Aug 91 1
2016 Jul 7 1
2016 May 29 1
2016 Apr 64 1
2016 Mar 31 1
2016 Feb 153 3
2016 Jan 118 1
2015 Dec 33 1
2015 Nov 131 1
2015 May 275 1
2015 Mar 895 4
2015 Feb 728 1
2014 Nov 2344 8
2014 May 492 6
2014 Apr 477 7
2014 Mar 1308 12
2013 Dec 80 1

Tags