CLISP Studio Release 2.7.0.0

Apr 23 2020

Clisp Studio 2.7.0.0 Release

1.1 Introduction

Clisp Studio version 2.7.0.0 is the first major revision released to the public in 2020. This significant update to Clisp Studio includes the introduction of new testing standards across many modules, addition of new instruments and many feature upgrades.

 

1.2 New Standards

Following recent revisions introduced by ASTM and BSI a number of new standards are now supported within Clisp Studio complementing the existing supported standards. The following standards have been introduced:

 

1.2.1 CS Triax - Total Stress Triaxial

BS EN 17892-7:2017 – Unconfined Compressive Strength

BS EN 17892-8:2018 – Unconsolidated Undrained Triaxial

ASTM D2850-15 – Unconsolidated Undrained Triaxial

ASTM D2166-D2166M-16 – Unconfined Compressive Strength

AS1289.6.4.1 – 2016 – Unconsolidated Undrained Triaxial

T171 – Modified Texas Triaxial Compression

 

Support the use of internal and external load cells

Support the use of fixed and domed top caps

 

1.2.2 CS Triax and CS Triax Advanced - Effective Stress Triaxial

BS EN 17892-9:2018 – Consolidated triaxial compression tests on water saturated soils

 

Support the use of internal and external load cells

Support the use of fixed and domed top caps

 

Both modules require an Internal load cell required for Anisotropic consolidation and K0.

CS Triax Advanced only - Internal load cell required for Stress Path and Cyclic control.


1.2.3 CS Res - Resilient Modulus

Materials Testing Manual Edition 4 - Q137 - Permanent deformation and resilient modulus of unbound material

AG Standard graphs & tables added for permanent deformation results and analysis. Multiple performance improvements in large data set calculation

 

1.2.4 CS CBR - CBR Testing

ASTM D1883-16 – Californian Bearing Ratio of a Laboratory Compacted Specimen

 

1.2.5 CS Oedo - Consolidation

ASTM D2435-11 - One-Dimensional Consolidation Properties of Soils Using Incremental Loading

 

1.2.6 CS Perm - Permeability Testing

BS EN17892-11:2019 – Permeability Testing

ASTM D5084-16 - Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter

 

1.3 New Features

Some of the new features added to this version of Clisp Studio include:

 

CS Stresspath now displays Mohr circles within the failure stage of the test.

 

CS Unsat now supports the use of on-sample transducers for the measurement of radial changes and small strain measurement; the use of fixed top caps is also now supported.

In CS Ringshear the British Standards now logs the outputs from the vertical displacement transducer and load cells through the preshear schedule. The test also now works out the average of the two load cells and logs and displays this for easy analysis of test data.

 

The soil steel interface test plan for the Ringshear system now has an additional stop criteria; this is to stop a test based on sample height change as well as the other features added to CS Ringshear.

 

The YouTube button within Clisp now takes you to our YouTube page instead of the video page on our website. The YouTube channel is updated more regularly to help provide you with better support and information about products and software.

 

CS Resilient standards now support the operation of a DSC1000 the latest VJ Tech dynamic system controller.

 

CS Dyna now support the operation of a DSC1000 the latest VJ Tech dynamic system controller.

 

CS Constant Shear now allows users to undertake multiple consolidation schedules.

 

New Colour coding has been added to Clisp to clearly show when a schedule is in a waiting state.

 

The new standards introduced into CS triax support the use of both internal and external load cells with use of both domed and fixed top caps (please check with VJ Tech to discuss compatibility of your system).

 

CS CRS now supports the use of instruments other than just APC’s for the feedback of pressure. This now allows the use of manual pressure control.

 

CS Triax Advanced now allows K0 consolidation testing that ramps the vertical stress and maintains the diameter of the sample using cell pressure control.

1.4 New Instruments

Clisp Studio now supports the additional new instruments:

 

1.4.1 DSC 1000 – Dynamic Servo Controller

 

This is VJ Tech’s latest dynamic controller and can be used with dynamic triaxal and resilient modulus systems.

1.4.2 VJT 2585-SS Direct and Simple Shear

The VJT 2585-SS is also now supported. This is a single shear machine than can perform both direct and simple shear tests.

1.4.3 VJT0650M-PHL – High Capacity ACONS

VJ Techs new high capacity (50kN) ACONS Pro is also now supported by this release of Clisp Studio.

1.5 New Test Modules

This release of Clisp sees the full introduction of the new CS Triax Advanced test module. This supports triaxial testing to the new BS EN 17892 triaxial standards. The module offers flexibility and testing options outside of the traditional standards. The module allows saturation, consolidation (Isotropic, anisotropic and K0), stresspath, static shearing and slow cyclic control. The module when used with the correct hardware can operate both compression and extension tests. The module also supports the use of on sample transducers and mid height pore water pressure measurement.

 

1.6 New Test Types

The version Clisp Studio allows users to undertake more test types than ever before. These include support for new international standards in triaxial, resilient modulus, permeability and CBR testing. The modules also allow the operation of differing testing scenarios such as K0 consolidation whilst ramping vertical stress, control of either effective or total stress in anisotropic consolidation and stress path analysis. The triaxial advanced module allows users to easily select between drained or undrained testing with a schedule. Slow cyclic testing up to 0.1Hz is also possible using a Pro series triaxial frame using the CS Triax Advanced module.

 

The Simple shear and dynamic simple shear modules now also support both constant normal height and constant normal stress during shearing. Constant normal stiffness tests are also supported using the cs constant shear module.

 

1.7 Miscellaneous

The following performance improvements have been included within this release:

Test plan navigation in tests with large number of schedules.

Variable calculation speed improved

Test Import speed improved

 

1.8 Fixes

 

Case

Title

1876

Read All Button on instrument panel - marked resolved - so closing for release notes

2246

csTriax - Implementation of ASTM D7181-11 (CD) standard - a new case is coming for the changes required for ASTm D 7181-20

2590

New Standard ASTM D2435/D2435M-11 - This is a duplicate of case 3030

2608

Export / Import Excel : Instrument calibration data - marked resolved so closing for release notes

2626

csPerm - Error in the calculation of permebaility - marked resolved - so closing for release notes

2658

Standard Review - csTriax - CU tests (D4767-11 standard) - done  to test

2667

STANDARDS FOR TODOS - done  to test

2669

csStressPath - Deviator stress calculation in stress path stage when using non fixed top cap - marked resolved so closing for release notes

2678

csTriax - Implementation of a new standard (Modified Texas Triaxial Compression Test) - marked resolved so closing for release notes

2812

cs triax - feature request - marked resolved - so closing for release notes

2822

csShear - Wrong report data when IMPORTING a test - marked resolved - so closing for release notes

2824

Feature request - add a button to views that show calculated variables to display variable definition - marked resolved - so closing for release notes

2839

feature request - warning message when starting schedule if channel is not selected from an instrument - marked resolved - so closing for release notes

2844

cs rowe -  extra graph available on all stages - marked resolved - so closing for release notes

2909

csTriaxADV - Stress path stopping condition  - This time I changed the UI slightly so that the user can choose the logic GREATER-THAN or LESS-THAN the signed strain value entered in the textbox. This makes it totally free to select the most appropriate condition.

2911

csUNSAT - Changes to work with fixed top caps - Fixes checked in v2.6.0.3776 (test plan 1.23) and work well.  Case is closing.

2913

feature request Cs stresspath - Add mohr circle graph to failure stage - marked resolved - so closing for release notes

2914

csUNSAT - Changes needed to use on-sample transducers with the module - All fixes have been tested and work well. Item 3 is fixed in case 2911. Case is closing.

2915

DSC1000 - Features and Fixes for csRes - marked resolved - so closing for release notes

2916

CSR- Acons 2 problem - marked resolved - so closing for release notes

2917

csSD-SWCC - Changes to be used with DW cell - Deleted 1 file from a past entry (#22056)

2919

CS Bender error message - Fixed. These menu options must be disabled for a Bender test because its plan doesn't have any logoc for triggering, logging or stopping conditions and there is no automation.  The reason for the message is that having erroneously allowed to run a ...

2922

CS Ringshear Feature request - Add logging to Preshear schedule - Check in clisp version 2.6.0.3766 and the feature request works.  checks included:  loggin data  excel export  script export  script import

2923

csShear Direct Shear tests -   - 1. Fixed  2. Fixed. The text "Trigger as soon as the stress exceeds..." was incorrect. It should read "When the error is less than the percentage"  3. Fixed. The reverse speed variables are located in the Shear schedule.  4. Fixed. The conversion ...

2924

csSimpleShear- speed problem - Matteo

2925

YouTube link - Done

2926

Pro Instrument Panel Mode updates - marked resolved - so closing for release notes

2928

csResilient - Issues when using the DSC-1000H - marked resolved - so closing for release notes

2930

cs triax advacned - solenoid valve not being opened or closed - marked resolved - so closing for release notes

2931

CS Shear -Selecting vertical controller with no vertical load cell feedback - marked resolved - so closing for release notes

2934

cs host - deleting logged transducer removes test data - checked in clisp version 2.6.0.3776 and is fixed

2936

cs host - formatting of tests assistant has some issues - marked resolved - so closing for release notes

2937

CS Oedo - unable to select pro series acons as controllers - checked in clisp version 2.6.0.3824

2939

Control feedback (Pro instruments) - marked resolved - so closing for release notes

2940

cs shear and shearscan pro - add feature to check displacement transducer reading against working range to stop shear stage runn - marked resolved - so closing for release notes

2941

cs shear - feature request for additional trigger condition - marked resolved - so closing for release notes

2942

cs triax - unconfined hardware assistant is broken - checked in clisp version 2.6.0.3824

2943

csShear, but might be a wider Clisp issue - data loss when re-calculation take splace - marked resolved - so closing for release notes

2944

cs totaltriax - texas triaxial issues - marked resolved - so closing for release notes

2946

cs total triax - Texas triaixal issues - marked resolved - so closing for release notes

2947

csTriax (new standards) - UU tests - BS EN ISO 17892-8 - Module was tested with CS v2.6.0.3800 and found to work well for all combinations of top caps and load cells.  Case is closing.

2948

CS total triax - Texas Triaxial - marked resolved - so closing for release notes

2949

csResilient - AG:PT/T053-07 - ok done.  fixed a few issues.  re-import customer table (its much faster now should only take 10 minutes), update to latest test plan.  re-open results tables to check

2951

csTriax (new standards) - UU tests - ASTM D2850 - All issues have been addressed (Issue 3: Very good spotted!!).  A final test with real sample will be done.  Vas.

2952

csTriax (new standards) - UC tests - BS EN ISO 17892-7 - marked resolved - so closing for release notes

2953

csTriax (new standards) - UC tests - ASTM D2166 - marked resolved - so closing for release notes

2954

csTriax (new standards) - UU tests - AS1289 - marked resolved - so closing for release notes

2955

Clisp studio - When an instrument goes into suspension (unsafe input) module keeps running - marked resolved - so closing for release notes

2956

BS 17892-9 2018: CD - Isotropic Consolidation - marked resolved - so closing for release notes

2957

BS 17892-9 2018: CD - Engage - marked resolved - so closing for release notes

2958

csTriax - Effective tests - BS 1377:8 - Description of t100 variable needs changing - marked resolved - so closing for release notes

2959

Clisp studio - Configuration export function - checked in clisp version 2.6.0.3824

2960

cs constant shear - wrong initial vertical value used after multiple consolidation schedules. - checked in clisp version 2.6.0.3824

2962

csResilient: Engage engine issue - marked resolved - so closing for release notes

2965

csResilient - Open Completed Resilient Modulus Table & Graph - marked resolved - so closing for release notes

2966

New BS Standard: issues - Issues checked in 2.6.0.3811 (test plan 1.03). New issues will be uploaded to a new case.  Case is closing.

2967

csRes - AG Standard : Notes - done.  to test

2969

Feature request - CS constant shear to be able to undertake multiple shear stages - marked resolved - so closing for release notes

2970

Feature request CS Ring for Fugro Wallingford - checked in clisp version 2.6.0.3824

2971

feature request Soil Steel Interface (ringshear) test plan - For Fugro Wallingford - checked in clisp version 2.6.0.3824

2977

cs host - formatting issue - marked resolved - so closing for release notes

2978

APCH Pro losing comms - marked resolved - so closing for release notes

2980

Colour coding for schedule that is waiting - marked resolved - so closing for release notes

2981

Cs ringshear - error message - marked resolved - so closing for release notes

2983

csTriax - BS EN ISO standards - CD tests - Fixed top cap - Fixes confirmed in v2.6.0.3831 (Test plan 1.05)  Case is closing.

2985

csTriax - BS EN ISO standards - CD tests - Domed top cap - The fix was confirmed in v2.6.0.3847 (test plan v1.07)
Case is closing

2987

Pro series instruments - Advanced read - marked resolved - so closing for release notes

2988

cs res - cannot select series 2 APC - marked resolved - so closing for release notes

2990

csTriax - BS EN ISO 17892-9 standards - Calculation of the machine speed - Checked on v2.6.0.3844 (Feature version, test plan 1.08).  Case is closing

2992

csTriax - BS EN ISO 17892-9 CU tests with domed - engage schedule doesn't trigger - Issue checked in v2.6.0.3837 (test plan 1.05)  Case is closing

2993

csTriax - BS EN ISO 17892-9 CU test - Issue fixed in v2.6.0.3831, case is closing.

2994

csTriax - BS EN ISO 17892-9 CU fixed top cap - Triscan reverses at the end of shear - Checked in v2.6.0.3831 (test plan v1.05).  Case is closing.

2995

csTriax - BS EN ISO 17892-9 - Calculation of current height and area during shear - Checked in v2.6.0.3844 (Test plan 1.08).  Case is closing

2996

csTriax BS EN ISO 17892-9 CU - domed - membrane and filter corrections - marked resolved - so closing for release notes

2997

csTriax - Effective stress tests - Mohr circles at the report are different than in the plot - marked resolved - so closing for release notes

2998

csTriax BS EN ISO 17892-9 CU tests - Domed - Strain calculation - Checked in v2.6.0.3844 (Feature version).  Case is closing

2999

BS EN ISO 17892-9 Fixed top caps - Load is changing while in triggering condition - marked resolved - so closing for release notes

3000

csTriax - Effective stress tests - BS EN ISO 17892-9 - Cosmetics issues - marked resolved - so closing for release notes

3001

csTriax - BS EN ISO 17892-9 CU with Fixed - Current diameter in Ko changes - marked resolved - so closing for release notes

3002

CS res - Cyclic stage still green after completing correct number of cycles - marked resolved - so closing for release notes

3003

cs triax adv - axial strain from the engage schedule is added to the following schedules - marked resolved - so closing for release notes

3004

csTriax BS EN ISO 17892-9 Domed top cap - Dimensions do not copy across specimens - Checked in v2.6.0.3844 (Feature version).  Case is closing.

3005

cs ring - first reading of corrected relative average displacement isn't 0 - marked resolved - so closing for release notes

3006

csTriax - BS EN ISO 17892-9 CU&CD tests - Calculation of Vertical Total Stress - Checked in v2.6.0.3844 (Feature version).  Case is closing.

3007

dynadss - consolidation UI is incorrect - marked resolved - so closing for release notes

3009

cs simple shear - vertical axis is not controlled by clisp in reverse stage - marked resolved - so closing for release notes

3010

cs triax adv - maintained test going into suspension - marked resolved - so closing for release notes

3011

cs simple shear - views not displaying correctly - checked in clisp version 2.6.0.3840 and is fixed

3012

csTriax - BS EN ISO 17892-9 CU&CD tests - Hardware setup - Checked in v2.6.0.3844 (Feature version).  Case is closing.

3013

cs simple shear - marked resolved - so closing for release notes

3014

cs shear and cs simple shear feature request - show the platen correct applied to normal stress - marked resolved - so closing for release notes

3015

csTriax - BS EN ISO 17892-9 CD tests - Add option to allow full automation - Checked in v2.6.0.3844 (feature version).  Case is closing.

3016

clisp studio exception message when opening  - marked resolved - so closing for release notes

3017

csTriax - BS En ISO 17892-9 - Soft soils option in hardware setup - Checked in v2.6.0.3844 (Feature version).  Case is closing

3018

csTriax - BS EN ISO 17892-9 - Automation problem - marked resolved - so closing for release notes

3019

Clisp studio - Can be opened in two windows at the same time - marked resolved - so closing for release notes

3020

Feature request for CS CRS - add back pressure feedback from instruments other than APC's - marked resolved - so closing for release notes

3021

csTriax - BS EN ISO 17892-8 (UU) with domed top cap - Checked in v2.7.0.3875, Mohr circles are now plotted correctly.  Case is closing.

3022

ASTM D2166/D2166M - 2016 - Unconfined Compressive strength of Cohesive Soil - Adding to Clisp - check in clisp verfsion 2.7.0.3874  and standard works as required

3023

csTriax - BS EN ISO 17892-7 (UC) with domed top caps - Calculation of vertical stress - Checked in v2.7.0.3875  Case is closing

3024

ASTM D2850-15 - Unconsolidared Undrained Traxial compression Test - Adding to Clisp - The changes have been done. It does need to be tested!

3026

Updated User Guides & Manuals - marked resolved - so closing for release notes

3030

NEW STANDARD - ASTM D2435/D2435M-11 (consolidation) into csOedo - Feneral Tables.  1. New default tables, BS and ASTM:Log or Sqrt for Oedometer time intervals.  2. Description and soil classification is provided n the Results view.  3. Procedure is entered in Initial Conditions (dimensions)  4. The Pre-Con is ...

3031

csDYNA - Implementation of the D5311-13 standard - Checked in v2.7.0.3875.  Case is closing.

3032

cs triax - bs 1377 part 8 isn't available - The UI has changed slightly (as agreed by VJTech)  The "free" options are either Total or Effective. The standards displayed will be only those applicable.

3033

cs triax - user can select effective stress test in total stress test - The way the standard js selected has changed, as agreed with VJTech. The user now has to select the type (Total or Effective) and then the available standards will be presented.

3034

Error in K0 ramps either vertical or horizontal stresses - Fixed, Test Plan 1.24 - However this includes an extra view to allow Benthix to enter ramp times more than 99 hours because their Clisp installation hasn't been upgraded yet. Once they've done that I will update the plan to the next version.

3035

csDYNA - "Include volume change during saturation" option - Checked in v2.7.0.3871. Case is closing

3036

Clisp studio - Filter option for database - Feature has been removed from Clisp v2.7.0.3871. Case is closing.

3037

csDYNADSS - Shear setup - DSC2000 !!!! I thought that wasn't supported anymore. However, the problem was an exception caused by calling a variable long long gone!  Once this exception fixed, everything works correctly. The Specimen/Copy bar is now hidden, but note that the ...

3038

CS triax - ASTM D2166/D2166M-13 listed in effective stress tests - checked in clisp version 2.7.0.3868

3039

cs triax - engage schedule setup is greyed out - checked in clisp version 2.7.0.3868 and is fixed

3040

cs triax - astm d4676-11stress path graph broken - checked in clisp version 2.7.0.3868 and is fixed

3041

cs triax - ASTM D7181-11 and D4767-11 - shear conditons ui not complete - checked in clisp version 2.7.0.3868 and is fixed

3042

cs triax - as 1289-2016 uu triaxial - specimen details UI descriptions are wrong - checked in clisp version 2.7.0.3868 and is fixed

3043

csRES - AG - Quick Shear Initial Data window - Checked in v2.7.0.3871. Case is closing

3044

cs triax - automation stopped - checked in clisp version 2.7.0.3868 and is fixed

3045

cs triax - shear stage has wring cell pressure in shearing schedule - Cannot reproduce.

3046

cs stresspath - test plan won't open for consolidation stage - Cannot reproduce.  I suspect the Test Plan being used is corrupted.

3049

csROWE - Custom unnecessary graph - Not really a bug. Perhaps all "user views, graphs or tables" should go into their own separate top menu? In theory you can create one of these using data from several stages. The way it is at the moment it can be accessed everywhere, that is all.

3050

csOedo- Report error message - done.  Also winrock, wincon, and marshall.  please check all reports in all modules are present

3051

CS cbr - after stop isn't setup correctly if preparation method is changed - checked in clisp version 2.7.0.3875

3052

csUNSAT - A test cannot be created - Issue fixed in v2.7.0.3871. Case is closing

3053

cs triax - ASTM D7181-2657 is a duplicate of ASTM D7181-11 - checked in clisp version 2.7.0.3875

3054

csPerm (using a Rowe cell) - Cannot assign the second servo of a Dual APC pro to Outlet controller - 1. Fixed. The Outlet controller was not saving the axis selection.  2. It seems in March 2015 there was a big cock-up when the Rowe plan was overwritten with the Triaxial one, and was then corrected in May the same year. Since the cock up Clisp ...

3055

csPerm (using a Rowe cell) - Cannot create Permeability schedules - Case is marked Resolved, it has been copied into 3054.  Vas.

3056

csOedo - BS EN ISO 17892-5 - Calculation of Cv and Mv - Fix checked in v2.7.0.3887.  Case is closing.

3057

csTriax & csTriaxAdv - Schedule Type Support - 1. Done - new Test Plan V1.25  2. csTriax does not include Anisotropic extensions. csEffectiveTriax does, and has been fixed as requested.  3. Done - the menus are disabled.  4. Done  5. For Peter.

3058

csPerm (using a Triaxial Cell) - Issues - 1. Test name removed  2. Changed. However, please note that if automated a perm schedule must continue with a consolidation schedule, and viceversa. Unless the "Run all Consolidations" option is selected. And then what if there are more perm ...

3059

Test Import - Instrument Creation - Implemented. I tested it by somebody else double check it please.

3060

cs triax - hardware form in astm d 2166-16 has incorrect title - checked in clisp version 2.7.0.3875

3061

cs triax - ASTM d 2166-16 - user can select platen as disaplcement feedback - Only available with 98598 - it is intentional.

3062

cs triax - basic issues with ASTM D 2850-15 - checked in clisp version 2.7.0.3875 and is fixed

3063

cs triax - astm d 2850-15 issue with selecting fixed top cap - checked in clisp version 2.7.0.3875 and is fixed

3064

CS CBR - Implmentation of ASTM D 1883-16 into Clisp Studio - checked in clisp version 2.7.0.3878

3065

Clisp studio - The installation folder has a different name - Changed to "vjtech" only in the Installation project,

3067

cs triax - astm d 2850-15 ipPreshearLoad varaible not working for fixed top caps - chceked in clisp version 2.7.0.3887

3069

csDSS - Shear Stage - Maintain Constant Normal Stress - fixed, Benthic will have to test it as we dont currently have access to a physical machine.

3070

csTriax - BS EN ISO standards (17892-8 & 17892-9) - UU, CU, CD tests - Base load with fixed top caps - ASTM D 2850-15 chcekd and works in clisp version 2.7.0.3887

 

 

Total: 0 Comment(s)

Latest Posts

Clisp Studio 2.9.0.0 Release
10/8/2020 1:54 PM | Vasileios
Introduction to Permeability Testing
9/11/2020 10:23 AM | Irina
Introduction to unsaturated triaxial testing
7/3/2020 2:27 PM | Vasileios
Introduction to Bender Element testing
7/3/2020 2:04 PM | Vasileios
CLISP Studio Release 2.7.0.0
4/23/2020 3:09 PM | Adrian Rose

Categories


Archives

2020 Oct 32 1
2020 Sep 106 1
2020 Jul 304 2
2020 Apr 86 1
2020 Feb 50 1
2019 Nov 1405 1
2019 Oct 37 1
2019 Jul 73 1
2019 Jun 141 3
2019 May 3147 1
2018 Mar 13329 1
2017 Oct 40477 1
2017 Aug 422 1
2016 Sep 64 1
2016 Aug 89 1
2016 Jul 7 1
2016 May 29 1
2016 Apr 61 1
2016 Mar 31 1
2016 Feb 149 3
2016 Jan 116 1
2015 Dec 33 1
2015 Nov 127 1
2015 May 266 1
2015 Mar 864 4
2015 Feb 708 1
2014 Nov 2306 8
2014 May 483 6
2014 Apr 468 7
2014 Mar 1292 12
2013 Dec 79 1