Clisp Studio version 2.10.1.0 is the final revision released to the public in 2020. This update to Clisp Studio includes the introduction of new testing standards, bug fixes and some feature upgrades.
1.2 - New Standards
Clisp Studio following on from the recent introduction of new BS EN standards in the UK for soil testing now includes support for BS EN 17892-10 for Direct Shear tests.

1.2.1 – Standards Supported in CS Shear
The CS shear module now includes support for the following test standards:
BS1377 – 7 (1995) – Determination of Shear Strength by Direct Shear
BS EN 17892 – 10 (2018) – Direct Shear Test
ASTM D3080-04 – Direct Shear Test of Soils under Consolidated Drained Conditions
ASTM D3080-D3080M-11 – Direct Shear Test of Soils under Consolidated Drained Conditions
AS 1289.6.2.2 : 1998 – Determination of the shear strength of soil – Direct Shear Test using a Shearbox
Q181C – Effective Angle of Internal Friction at Constant Volume Conditions for Granular Materials
1.3 - New Features
A number of new features have been introduced into Clisp Studio relating to calibration of transducers using Pro series instruments. A new excel export feature has also been introduced.
1.3.1 – Ghost Channels
Clisp now supports the option to store multiple calibrations on a single channel. This allows multiple transducers to be stored on one channel so that the most appropriate transducer can be selected for the test without the need to recalibrate it.

1.3.2 – Soft Tare Function
A soft tare function has been introduced for channels calibrated in load on Pro Series instruments. This allows the user to zero a load cell (to remove drift) without effecting the calibration of the load cell.

1.3.3 – All Input Values Excel Export
From the main export menu a new option is available that allows a test to be exported to excel so that all transducer inputs values from a test will be displayed on a single excel spreadsheet. This allows a user to see the entire history of a test easily, without needing to move to differing tabs or files.

1.4 – New Instruments
Support for new automatic pressure controllers has also now been included. The new models are VJT2266-P7 (100 bar pressure controller), VJT2266A-P14 (140 Bar Pressure Controller) and VJT2266A-PHS (high speed pressure controller).

1.5 – Other News
This version of Clisp Studio also includes the following:
· Support for the New Ringshear Pro
· A number of bug fixes and improvements across the new BS EN triaxial standard tests
· CS Marshall now includes a user defined setup allowing nonstandard tests to be performed.
1.6 - Fixed Cases
Case
|
Title
|
Status
|
6296
|
CS Ringshear - Manually stopping a schedule with wait after stop and then starting another schedule causes clisp to hang
|
Resolved (Fixed)
|
6295
|
csTriax - BS En ISO 17892 CU&CD tests (csEffectiveTriax) - Cell and Back pressures at shear stage
|
Closed (Fixed)
|
6294
|
csTriax - BS EN ISO 17892-9 standard (CU - csEffectiveTriax) - After stop control for the load frame
|
Closed (Fixed)
|
6291
|
k0 csTriaxialADV = fix for height
|
Closed (Fixed)
|
6290
|
CS dyan - importing script the test data isn't displayed in clisp
|
Closed (Fixed)
|
5288
|
csSimpleShear - ASTM D6528-17 - Shear stage doesn't trigger
|
Closed (Fixed)
|
5287
|
csShear - Q181C - Shear summary graph doesn't include the peak shear stress
|
Closed (Fixed)
|
5286
|
Soil Steel Interface ringshear test plan - Error message when adding additional fast shear stages
|
Closed (Fixed)
|
5285
|
csShear - ASTM D3080-11 - Shear report needs to include the vertical stress
|
Closed (Fixed)
|
5284
|
Shearscan Pro - Engage button on horizontal axis in Clisp studio
|
Closed (Fixed)
|
5282
|
csShear - BS 1377-7 - Residual shear - Reverse speed bounches back to the default
|
Closed (Fixed)
|
5280
|
Clisp studio - Ghost channels - FSD and Divisions at Full Scale are not copied
|
Closed (Fixed)
|
5277
|
soil steel interface ringshear - vertical displacement transducer reading is wrong
|
Closed (Fixed)
|
5276
|
csBender - List of changes needed
|
Closed (Fixed)
|
5274
|
Clisp Studio - exporting calibrations that have ghost channels
|
Closed (Fixed)
|
5273
|
Clisp Studio - Ghost channel issue with units
|
Closed (Fixed)
|
5272
|
cs oedo - Mv is using wrong unit
|
Closed (Fixed)
|
5271
|
soil steel ringshear test plan - reverse stage doesn't use the speed entered in setup
|
Closed (Fixed)
|
5268
|
cs ringshear - shear stage setup, UI formatting covering some of the setup
|
Closed (Fixed)
|
5267
|
cs ringshear - old ASTM and BS standard - Preshear not traveling in right direction
|
Closed (Fixed)
|
5266
|
ghost calibration channel issue - working range cannot be set independently
|
Closed (Fixed)
|
5265
|
Issue with Ghost channel calibration
|
Closed (Fixed)
|
5264
|
cs ringshear feature request - add additional graph to shear stage of BS EN standard test
|
Closed (Implemented)
|
5263
|
Soil Steel Interface Ringshear test plan - issues with stopping a Pro series ringshear
|
Closed (Fixed)
|
5262
|
creating a test issue - can't access standards drop down
|
Closed (Fixed)
|
5260
|
End Of Primary Consolidation (csOedo)
|
Resolved (Implemented)
|
5259
|
shearscan pro firmware 1.65 issues
|
Closed (Fixed)
|
5258
|
csTriax (csTotalTriax) - BS EN ISO 17892-8 standard - Shear setup window gets corrupted
|
Closed (Fixed)
|
5254
|
csShear - Calculation of the target load in consolidation should take into account the platen correction
|
Closed (Fixed)
|
5253
|
Shear modules - Platen correction applied to the Normal Stress
|
Closed (Fixed)
|
5252
|
custom images in reports
|
Resolved (Fixed)
|
5251
|
Cs simple shear and Cs Dynadss report issues
|
Closed (Fixed)
|
5249
|
CS res - remove membrane correction from Q137
|
Closed (Fixed)
|
5248
|
csDYNA - Cosmatics issue in Ko consolidation Initial Data window
|
Closed (Fixed)
|
5247
|
New Instrument Variants DSC3003M / MM
|
Closed (Implemented)
|
5246
|
Clisp studio - AGS export function
|
Closed (Fixed)
|
5245
|
(Untitled)
|
Closed (Fixed)
|
5244
|
csTriax - BS EN ISO 17892-9 CU CD tests - Cosmetics issue in consolidation initial data screen
|
Closed (Fixed)
|
5243
|
Q137 - First Run of newly created test
|
Closed (Fixed)
|
5242
|
csRes AG Standard Engage Schedule
|
Closed (Fixed)
|
5241
|
cs triax - Total stress New AS standard - Error message when trying to run shear schedule
|
Closed (Fixed)
|
5239
|
CS dynadss - Absolute waveforms (load control) are not starting from 0 load
|
Closed (Fixed)
|
5238
|
exception message in cs dyna
|
Closed (Fixed)
|
5234
|
cs res - q137 standard - deviator stress calculation change
|
Closed (Fixed)
|
5233
|
csTriax - ASTM UU tests - Membrane correction
|
Closed (Fixed)
|
5232
|
RingShear pro Vertical Load
|
Closed (Approved)
|
5231
|
csTriax - UU tests using a Triscan pro - Shear rate improvement
|
Closed (Fixed)
|
5230
|
CS triax - be en cu triaxial - DSC3000 unloads after the aniotropic schedule goes into a maintained state
|
Closed (Fixed)
|
5229
|
CS triax - BE EN Standard - Open and close back pressure valve message not working
|
Closed (Fixed)
|
5228
|
csTriax - UU (total stress) Temperature Controlled tests (all standards) - Triggering conditions
|
Closed (Fixed)
|
5226
|
csTriax - Temperature controlled tests - ASTM CU&CD tests - Hardware setup cannot be applied
|
Closed (Fixed)
|
5225
|
csShear - Residual direct shear. (new BS ENISO standard)
|
Closed (Fixed)
|
5224
|
cs res - q137 standard - stopping condition variable (IsCycleCountReady) needs cycle active added to definition
|
Closed (Fixed)
|
5223
|
csRingshear - ASTM D6467-13 - Preshear schedule automation
|
Closed (Fixed)
|
5222
|
DSC3000 - restarting automatically after restart shouldn't do this
|
Closed (Fixed)
|
5221
|
cs dyandss - shear schedules have the same trigger condition shown twice
|
Closed (Fixed)
|
5220
|
cs dynadss - exception message
|
Closed (Fixed)
|
5219
|
csTriax - BS1377-8 standard (effective stress) - t100 label is showing t50
|
Closed (Fixed)
|
5217
|
csMarshall - New Test Variant
|
Closed (Implemented)
|
4214
|
Analogue Channels - Soft Tare
|
Closed (Implemented)
|
4212
|
Analogue Channel Calibration Sets
|
Closed (Implemented)
|
4206
|
csDYNA - Axial strain calculation in the Stress Path stage
|
Closed (Fixed)
|
4183
|
CS host - adding second stage causes time to break
|
Closed (Fixed)
|
2648
|
csDYNA, csDYNADSS, csDYNADSS-C - Replace "Miantain current position" with "Maintain current level"
|
Closed (Fixed)
|